- Assisted Control Mandatory Ventilation (CMV)
- Synchronized Intermittent Mandatory Ventilation (SIMV)
- Spontaneous Ventilation (CPAP + PS, CPAP + VS, SPAP)
|
| |
- Automatic Tube Compensation
- Work of Breathing, Imposed
- Reference Loop Save Feature
- Maneuvers: P0.1 and PiMax
- Auto Control
- Apnea Backup Ventilation
- SPAP Philosophy Options: Time, Cycle + Time, Cycle + I:E
- IBW Calculator
- NIV On/Off in all Modes
- Active Exhalation Valve
- Automatic Leak Compensation (up to 60 lpm)
- User defined flow sensor position
- Proximally at the circuit Wye
- Distally at the Expiratory Port
|
| |
- Spontaneous Breathing Trial (SBT Mode)
- Tube Compensation
- Suction Support
- Recruitment Maneuver Tools
- Pressure Slow Inflation / Deflation Maneuver
- Volume Slow Inflation / Deflation Maneuver
- Step Tool
|
| |
|
|
|
(V-CMV; V-SIMV)
|
|
|
|
(P-CMV; P-SIMV, PS)
|
- Volume Targeted Pressure-controlled
|
|
(PRVC-CMV; PRVC-SIMV, VS)
|
|
|
|
(SPAP)
|
- Equivalent to APRV (CareFusion)
& BiLevel (Covidien)
|
|
| |
|
|
|
0.5 - 20 cmH2O
|
|
|
|
0.1 - 25 lpm
|
|
| |
|
|
|
0 - 150 bpm
|
|
|
|
2 - 2000 ml*
|
|
|
|
0 - 50 cmH2O
|
|
|
|
2 - 90 cmH2O*
|
|
|
|
0 - 90 cmH2O
|
|
|
|
1 - 120 lpm*
|
|
|
|
Up to 180 lpm*
|
|
|
|
0.1 - 10 sec
|
|
|
|
21 - 100%
|
|
|
|
1 - 20
|
- Exhalation sensitivity %
(of spontaneous peak flow)
|
|
10 - 80%
|
- Base Flow (with leak comp off)
|
|
2.5 - 25 lpm
|
|
|
|
0 - 42 sec (0 - 70%)
|
|
|
|
0.15 - 5.0 sec*
|
|
| |
- Multiple Easy View Tabs
(Main, Settings, Monitoring, Alarms, Configuration)
|
|
|
- Manual & Automatic Time Based Event Markers
|
|
|
- Graphics Display (3-Loops and 3-Waveforms)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- Humidification Selection (HME, Humidifier, and None)
|
|
|
|
|
|
0 - 80%*
|
- User Defined Custom Default Settings
|
|
|
|
| |
- Manual inspiration
- Alarm silence
- 100% Oxygen* (+20% Oxygen (Neonate))
- Inspiratory and expiratory breath holds
- Standby
|
| |
- Delivered oxygen concentrations:
|
|
21 - 100%
|
- Trend Data (1-72 hrs.) (34 trend parameters)
|
|
|
- Monitoring Data (41 monitored parameters):
|
|
|
| |
- Auto set alarm feature & 1000 Event log
|
| |
- Ethernet and Nurse call, RS232
|
| |
- AC power: 100 - 240 VAC (50/60Hz)
- Internal and optional external battery
- Screen: LCD 12.1” / Touch Screen
- Internal Compressor (optional)
- Battery backup on compressor < 120 min, off compressor > 120min
- Gas supply 2 -6 Bar
- Integrated CliniNet® Server with SNMP
|
| |
- CliniNet® Virtual Report™ Software
|
| |
|
* Patient Type Dependent
|
| |
|