eVolutions 3e Ultra Ventilator
|
-
|
|
|
Highlights
In addition to all the advantages of its predecessor, the eVolution 3e, this model incorporates the option for monitoring esophageal pressure, recruitment maneuvers, SpO2, improvements in trigger and performance in NIV, and more information aimed at helping clinicians make more informed decisions about their patient's treatment. All of this is displayed on the new 15-inch screen with an updated GUI designed specifically for clinicians.
A full suite of modes gives the clinician the flexibility to choose the mode that best suits the patient’s needs.
|
|
 |
|
-
|
|
|
Features
- Easy to use 15” touchscreen.
- Neo, Ped, Adl
- 74 Monitoring Parameters
- Recruitment Maneuvers
- Target Tool for All modes
- High efficiency Turbine
- CO2 Monitoring
- SpO2 Monitoring
- 4 Hours Battery
- Auxiliary Pressure port (Paux/Pes)
- HDMI Output
|
|

|
|
-
|
|
|
|
International Specifications
|
| |
- Assisted Control Mandatory Ventilation (CMV)
- Synchronized Intermittent Mandatory Ventilation (SIMV)
- Spontaneous Ventilation (CPAP + PS, CPAP + VS, SPAP, nCPAP, nIMV)
- Dual Modes (ACM)
- High Flow Oxygen Therapy
|
| |
- Auto Control
- Apnea Backup Ventilation
- SPAP Philosophy Options: Time, Cycle + Time, Cycle + I:E
- IBW Calculator
- Interfaces Philosophy: Intubated, Mask, and Cannula
- Esophageal Pressure Monitoring (1)
- SpO2 and Volumetric CO2 Monitoring (2)(3)
- Automatic Leak Compensation (up to 60 lpm)
- Work of Breathing
- Maneuvers: Recruitabilty and Weaning
- Target Tool for All Ventilation modes
- Day and light configuration
- SAT - Slope Analysis Trigger – for NIV
- Apnea Back-up
- User-selected breath type and settings
- Smart Nebulizer™
- Smart Sigh™
- Humidification Selection (HME, Humidifier, and None)
|
| |
|
|
|
(V-CMV; V-SIMV)
|
|
|
|
(P-CMV; P-SIMV, PS)
|
- Volume Targeted Pressure-controlled
|
|
(PRVC-CMV; PRVC-SIMV, VS)
|
|
|
|
(SPAP)
|
- Equivalent to APRV
& BiLevel
|
|
| |
|
|
|
-0.5 to (-20) cmH2O
|
|
|
|
0.1 - 25 lpm
|
|
| |
|
|
|
1 - 150 bpm
|
|
|
|
2 - 3000 ml
|
|
|
|
0 - 50 cmH2O
|
|
|
|
1 - 100 cmH2O
|
|
|
|
0 - 100 cmH2O
|
|
|
|
1 - 150 lpm
|
|
|
|
Up to 180 lpm
|
- Peak flow (Turbine Output)
|
|
Up to 300 l/min
|
|
|
|
0.1 - 10.0 sec
|
|
|
|
21 - 100%
|
|
|
|
1 - 20
|
- Exhalation sensitivity %
(of spontaneous peak flow)
|
|
1 - 80%
|
- Base Flow (with leak comp off)
|
|
2.5 - 25 lpm
|
|
|
|
0 - 2.0 sec
|
|
|
|
0.15 - 5.0 sec
|
|
| |
- Option - SpO2
- Option - PAux, Pes
- Option - Paramagnetic O2 sensor
- Volumetric Capnography Kit, VCO2
|
| |
- Multiple Easy View Tabs
(Main, Settings, Monitoring, Alarms, Configuration)
|
|
|
- 3 Graphic Windows, each of them can show 2-Loops, 3-Waveforms, 16 Monitored Data (GW1 32),
graphical and tabular trends, Lung Tool or Target Tool
|
|
|
|
|
|
|
|
|
|
|
|
| |
- Manual inspiration
- Alarm silence
- 100% Oxygen
- Inspiratory and expiratory breath holds
- Standby
|
| |
- Delivered oxygen concentrations: 21 - 100%
|
|
|
- Trend Data (1-72 hrs.) (31 trend parameters)
|
|
|
- Monitoring Data (74 monitored parameters):
|
|
| |
- Auto set alarm feature & 1000 Event log
|
| |
- Ethernet, Nurse call, HDMI
|
| |
- AC power: 100 - 240 VAC (47/63Hz)
- Standard Internal Battery (Lithium-Ion)
- Battery backup 4 hours
- Gas supply pressure, 2 to 6 Bar
- Screen: LCD 15” / Touch Screen
|
| |
- CliniNet® Virtual Report™ Software
|
| |
- Integrated high performance turbine technology(4)
- Low Flow O2, 0.3 to 2 Bar
|
| |
- Model EVL100500-T-L, High Pressure System, hotwire internal flow sensor
- Need Paux/Pes option
- Need SpO2 Option
- Need CO2 Option
- Only available on turbine models
|
| |
|
Specifications subject to change. eVent Medical recommends using exhalation filters on all systems.
|
|
|
|
|