Assisted Control Mandatory Ventilation (CMV)Synchronized Intermittent Mandatory Ventilation (SIMV)Spontaneous Ventilation (CPAP + PS, CPAP + VS, SPAP) | 
|  | 
| 
|  |  | (V-CMV; V-SIMV) |  
|  |  | (P-CMV; P-SIMV, PS) |  
| 
Volume Targeted Pressure-controlled |  | (PRVC-CMV; PRVC-SIMV, VS) |  
|  |  | (SPAP) |  
| 
Equivalent to APRV (CareFusion) & BiLevel (Covidien)
 |    | 
| 
|  |  | 0.5 - 20 cmH2O |  
|  |  | 0.1 - 25 lpm |  | 
|  | 
| 
|  |  | 0 - 150 bpm |  
|  |  | 2 - 2000 ml* |  
|  |  | 0 - 50 cmH2O |  
|  |  | 1 - 90 cmH2O* |  
|  |  | 0 - 90 cmH2O |  
|  |  | 1 - 120 lpm* |  
|  |  | Up to 180 lpm* |  
|  |  | 0.1 - 10 sec |  
|  |  | 21 - 100% |  
|  |  | 1 - 20 |  
| 
Exhalation sensitivity %(of spontaneous peak flow)
 |  | 10 - 80% |  
| 
Base Flow (with leak comp off) |  | 2.5 - 25 lpm |  
|  |  | 0 - 42 sec (0 - 70%) |  
|  |  | 0.15 - 5.0 sec* |    | 
| 
Work of Breathing, ImposedReference Loop Save FeatureManeuvers: PO.1 and PiMaxAuto ControlApnea Backup VentilationSPAP Philosophy Options: Time, Cycle + Time, Cycle + I:EIBW CalculatorNIV On/Off in all ModesActive Exhalation ValveAutomatic Leak Compensation (up to 60 lpm)User defined flow sensor position
Proximally at the circuit WyeDistally at the Expiratory Port   | 
| 
Volumetric Capnography (VCO2) / Time Based Capnography (ETCO2)Tube CompensationSpontaneous Breathing Trial (SBT Mode)Suction SupportRecruitment Maneuver Tools
Pressure Slow Inflation / Deflation ManeuverVolume Slow Inflation / Deflation ManeuverStep Tool High flow oxygen   | 
| 
Manual inspirationAlarm silence100% Oxygen* (+20% Oxygen (Neonate))Inspiratory and expiratory breath holdsStandby | 
|  | 
| 
| 
Multiple Easy View Tabs(Home, Settings, Alarms, Maneuver and Config)
 |  |  |  
| 
Manual & Automatic Time Based Event Markers |  |  |  
| 
Graphics Display (Waveforms, Loops, Data, Trends, Trends Tabs and Event Markers) |  |  |  
|  |  |  |  
|  |  |  |  
|  |  |  |  
| 
Humidification Selection (HME, Humidifier, and None) |  |  |  
|  |  | 0 - 80%* |  
|  |  |  |  
|  |  |  |  
| 
User Defined Custom Default Settings |  |  |  | 
|  | 
| 
| 
Delivered oxygen concentrations: 21 - 100% |  |  |  
| 
Trend Data (1-72 hrs.) (46 trend parameters) |  |  |  
| 
Monitoring Data (53 monitored parameters): |  
| 
| Basic |  | Mechanics |  | Weaning |  | ETCO2 |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
|  |  |  |  |  |  |  |  
 
| Real Time Graphics |  | ETCO2 Real Time Graphics |  
|  |  |  |  
|  |  |  |  
|  |  |  |  
|  |  |  |  
|  |  |  |  
|  |  |  |  |  | 
|  | 
| 
Auto set alarm feature & 1000 Event log | 
|  | 
| 
Ethernet and Nurse call, RS232Integrated CliniNet® Server with SNMPCliniNet® Virtual Report™ (Optional Remote Viewing System Software) | 
|  | 
| 
AC power: 100 - 240 VAC (50/60Hz)Internal and Optional External BatteryScreen: LCD 17” / Tiltable and Rotatable Touch ScreenInternal Compressor (Optional)Integrated CartBattery backup on compressor < 120 min, off compressor > 120minGas supply 2 -6 Bar   | 
| 
Model F7300000-7i-L : Inspiration 7i Ventilator - 17" ScreenModel F7300000-7i-L-NC : Inspiration 7i Ventilator - 17" Screen without internal compressor | 
|  | 
| * Patient Type Dependent | 
| Specifications subject to change. | 
|  | 
|  |