- Assisted Control Mandatory Ventilation (CMV)
- Synchronized Intermittent Mandatory Ventilation (SIMV)
- Spontaneous Ventilation (CPAP + PS, CPAP + VS, SPAP)
|
|
- Auto Control
- Apnea Backup Ventilation
- SPAP Philosophy Options: Time, Cycle + Time, Cycle + I:E
- IBW Calculator
- NIV On/Off in all Modes
- Active Exhalation Valve
- Automatic Leak Compensation (up to 60 lpm)
- Work of Breathing Imposed
- Maneuvers: PO.1 and PiMax
|
|
|
|
(V-CMV; V-SIMV)
|
|
|
(P-CMV; P-SIMV, PS)
|
- Volume Targeted Pressure-controlled
|
|
(PRVC-CMV; PRVC-SIMV, VS)
|
|
|
(SPAP)
|
- Equivalent to APRV
& BiLevel
|
|
|
|
|
-0.1 to (-20) cmH2O
|
|
|
0.1 - 25 lpm
|
|
|
|
|
1 - 120 bpm
|
|
|
20 - 3000 ml
|
|
|
0 - 50 cmH2O
|
|
|
1 - 100 cmH2O
|
|
|
0 - 100 cmH2O
|
|
|
1 - 120 lpm
|
|
|
Up to 180 lpm
|
- Peak flow (Turbine Output)
|
|
Up to 300 l/min
|
|
|
0.2 - 10.0 sec
|
|
|
21 - 100%
|
|
|
1 - 20
|
- Exhalation sensitivity %
(of spontaneous peak flow)
|
|
1 - 80%
|
- Base Flow (with leak comp off)
|
|
2.5 - 25 lpm
|
|
|
0 - 2.0 sec
|
|
|
|
|
|
|
|
1 - 150 bpm
|
|
|
2 - 3000 ml
|
|
|
0.1 - 10 sec
|
|
|
0.15 - 5.0 sec
|
|
|
|
|
Part Number: EVM400158
|
- Automatic tube compensation
|
|
Part Number: EVM400157
|
|
|
Part Number: EVM400182
|
|
|
Part Number: EVM400184
|
|
|
- Multiple Easy View Tabs
(Main, Settings, Monitoring, Alarms, Configuration)
|
|
|
- Graphics Display (2-Loops and 3-Waveforms)
|
|
|
- Apnea Back-up
- User-selected breath type and settings
|
|
|
|
|
|
|
|
|
- Humidification Selection (HME, Humidifier, and None)
|
|
|
|
|
|
|
|
|
|
|
- Manual inspiration
- Alarm silence
- 100% Oxygen
- Inspiratory and expiratory breath holds
- Standby
|
|
- Delivered oxygen concentrations: 21 - 100%
|
|
|
- Trend Data (1-72 hrs.) (31 trend parameters)
|
|
|
- Monitoring Data (36 monitored parameters):
|
Real Time Graphics
|
|
EtCO2 Graphics
|
|
EtCO2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- Auto set alarm feature & 1000 Event log
|
|
|
|
- AC power: 100 - 240 VAC (47/63Hz)
- Standard Internal Battery (Lithium-Ion* & Lead Acid**)
- Battery backup > 120min
- Gas supply pressure, 2 to 6 Bar
- Screen: LCD 12.1” / Touch Screen
|
|
- CliniNet® Virtual Report™ Software
|
|
- Integrated high performance turbine technology*
- Low Flow O2, 0.3 to 2 Bar*
|
|
- Model EVL100500-HP, High Pressure System
- Model EVL100500-T, Internal Turbine System
- Model EVL100500-HP-NF, High Pressure System without Exhalation Filter
- Model EVL100500-T-NF, Internal Turbine System without Exhalation Filter
|
|
* Only available on turbine models
** Only available on high pressure models
Specifications subject to change. eVent Medical recommends using exhalation filters on all systems.
|
|
|